Ôîðóì » Âåñû êèòàéñêèõ ïðîèçâîäèòåëåé » Êàëèáðîâêà òåðìèíàëà XK3118T4 » Îòâåòèòü

Êàëèáðîâêà òåðìèíàëà XK3118T4

Suse: Ïðèâåò,ïîìîãèòå ñ êàëëèáðîâêîé òåðèíàëà XK3118T4.ïåðåíàæèìàë óæå âñå êîìáèíàöèè,íåçíàþ êàê ( http://en.kelichina.com/uppics/2009290564654262.jpg Ïîìîãèòå!

Îòâåòîâ - 11

upk: îòïðàâèë íåñêîëüêî êàëèáðîâîê ýòîéæå ôèðìû , ìîæåò ÷òî- òî ïîäîéäåò.Ñìîòðè ïî÷òó

Suse: Áîëüøîå ñïàñèáî!

Suse: upk Ïîïðîáîâàë,íå êàòÿò((


Suse: *PRIVAT*

ìñì: âûêëàäûâàé

Suse: ïî÷åìó áû íå ñäåëàòü áèáëèîòåêó êàëèáðîâîê ïðèáîðîâ?

Suse: Âûêëàäûâàþ: PSC-1 I. Calibration After self inspection when power on, it displays weight normally, warm-up about 15 to 30 minutes, to confirm that threshold of “JP-CAL” on indicator main panel is already plugged to short circuit cap, then the steps as below: Step Operation Display Remarks 1 Press “Fn”for a long time 【Fn SEt】 Enters to parameter setting 2 Press “ ”“ ”enter to calibration 【 CAL 】 It means to enter to calibration state, press “ ” to next step 3 “ ”to select division value, “ ”to confirm 【E 01】 Set division value: 1, 2, 5, 10, 20, 50 4 “ ” to select decimal “ ”to confirm 【dC 0】 Set position of decimal: indicator shows position of decimal in intuitive way 5 Set full capacity 【F030.00】 Set full capacity: Press “→”, the glittering digit to move to right “ ”to increase glittering digit number “ ”to confirm, and enters to next step, 3000 for example 6 After stable, press to confirm 【noLoAd】 Zero calibrating: indicator under noload condition, press “ ”to confirm zero after its stable 7 Enter adding weights value 【AdLoAd 】 Changing to add load automatically after 2 seconds Enter【003.000】 Linearity: add load, the closer to full capacity the better, operation is the same as setting full capacity. After stable light is bright for 5 seconds, press “ ” to confirm, and to exit calibration automatically, 3000 for example 8 Return back to working state 【 End 】 【 3.000】 Calibration is finished, display “End” and display current weight after 2 seconds. ★If you want to exit from calibration during any condition, you can press “Fn” to exit. The changed calibrating data will not be saved. It is original calibrating parameters when power on again. II. Other Calibration Parameter Setting After display 【CAL】, press “ ” , indicator displays 【Zero】, then press “ ” to enter to other calibrating parameter setting. Detailed steps are as below: Step Operation Display Remarks 【Zero】 Enter to other calibrating parameters setting, press “↙”to next step 1 “ ”to switch “ ”to confirm 【Zot *.*】 Zero tracing range: 0~4d 2 “ ”to switch “ ”to confirm 【nt **】 Manual set zero range: 0,2,4,10,20,100 % of full capacity 3 “ ”to switch “ ”to confirm 【At **】 Auto set zero range: 0,2,4,10,20,100 % of full capacity Select 【--】 to save power off zero function, that is to say, zero which was manual set when power off of last time is the zero of power on next time, no auto set zero is needed again. 4 “ ”to switch “ ”to confirm 【FL ***】 Filter setting: 【Stb】:Stable 【SEn】:Sensitive 5 “ ”to switch “ ”to confirm 【SPd *】 AD speed selection: 【0】:slow 【1】:quick ( slow is suitable for general occasion, quick is suitable for special occasion which require high speed http://slil.ru/27717329 ïàðîëü 123456

upk: ñïàñèáî. ñàì ñìîã íàéòè â èíòåðíåòå èíñòðóêöèþ ïî ýêñïëóàòàöèè äà è òî íà êèòàéñêîì

Suse: ))òàê æå áûëî.íî ýòà à àíëèéñêîì

Suse: Ïåðåâîä÷èêè: http://slovari.h15.ru/chi-1.php

ragida: âåñû XK 3118 T10 ïðè âêëþ÷åíèè âûäàþò îøèáêó ERR 08 ÷òî ýòî òàêîå ïîäñêàæèòå ïîæàëóéñòà.



ïîëíàÿ âåðñèÿ ñòðàíèöû